Searching for: Wood

Searching results for “Wood”
520 results found...
Sort By Dropdown Icon

Acoustic Comparative Study

In a context where wood construction is gaining momentum, acoustics remains a key challenge in ensuring occupant comfort and compliance with standards. With this in mind, AcoustiTECH, an expert in acoustic solutions, has partnered with FPInnovations, a leader in research and development in the wood sector, to conduct an in-depth comparative study in its laboratory facility.

Who We Are

AcoustiTECH is a broker specializing in acoustic solutions, supporting building professionals in selecting highperformance materials that meet and exceed industry standards. With 25 years of experience and unique expertise, we offer customized assemblies through a specialized brand ecosystem and reliable data. Our personalized service, backed by dedicated technical and engineering teams, ensures tailored and effective
solutions that enhance the acoustic comfort of occupants. FPInnovations is a globally recognized, private, non-profit organization specializing in research and development for the forestry sector. Its mission is to support businesses and building professionals in innovating and optimizing wood-based materials. With ISO 17025-accredited laboratories and state-of-the-art facilities, FPInnovations assesses the performance of wood structures in terms of acoustics, vibrations, fire resistance, and more.

Study Objective

At AcoustiTECH, our goal is to continuously innovate by delivering new data and acoustic solutions tailored to the specific requirements of each project. This collaboration with FPInnovations marks a significant milestone in our acoustic analysis of wood structures, as it represents our first large-scale data collection on a GLT masstimber slab and our second mass-timber campaign overall, building on a prior study.

Through this study, we obtain precise acoustic measurements for this structural system and conduct rigorous comparisons across numerous innovative market solutions. We take into account key project criteria such as acoustic performance, budget, thickness, weight, and even design, as different acoustic solutions can also influence the choice of floor coverings.

Grounded in a scientific approach and conducted in controlled environments with FPInnovations, this research aims to evaluate various acoustic configurations optimized for mass timber construction. By combining technical expertise, innovation, and in-depth analysis, we provide architects, engineers, and developers with high-performance solutions that meet and exceed the industry standards.

Shearwalls – Canadian Version

WoodWorks®

Shearwalls 2025

$250 /yearly subscription (CAD) Conforms to CSA O86-24 and NBC 2020
  • Automatically generates wind loads following the Directional or Envelope procedure in ASCE 7
  • Automatically generates seismic loads following the Equivalent Lateral Force procedure in ASCE 7
  • Distributes lateral loads to shear lines according to flexible and rigid diaphragm analyses
  • Distributes lateral loads within shear lines based on shear wall stiffness or capacity
  • Implements limitations and provisions for structural irregularities in ASCE 7
  • Designs full-height wall segmentsforce-transfer shear walls, and perforated shear walls with wood, gypsum, fiberboard and lumber sheathing
  • Designs shear walls for sheathing, nailing and hold-down connections
  • Optimizes shear wall design by iterating and automatically selecting the most economical sheathing and nailing patterns
  • Designs components & cladding for out-of-plane wind loads
  • Calculates shear wall deflection using “3-term” or “4-term” deflection equations
  • Checks story drift for wind and seismic
  • Determines anchor bolt, collector and force-transfer strap forces
  • Allows additional manual load inputs
  • Import .pdf, .bmp, .wmf and .emf files from AutoCAD as templates for floor layouts


  Detailed and transparent reporting of results, including:


Did you know? 
Modelling a structure is quick and easy: start from a blank slate or use a pdf or wmf file as a template. See our video showing how typical buildings can be modeled in minutes!

Software Edition

A 10-day trial period activates upon installation
Image for illustrative purposes only. This is a digital product. No physical item will be provided.
Shearwalls - Canadian Version

WoodWorks®

Sizer

WoodWorks® Sizer – Size beams, joists, columns, wall studs and panels constructed from lumber, timber, glulam, structural composite lumber, I-joists and CLT.

$210 /yearly subscription (USD)
A 10-day trial period activates upon installation

Software Edition

Image for illustrative purposes only. This is a digital product. No physical item will be provided.

Shearwalls - Canadian Version

WoodWorks®

Shearwalls

WoodWorks® Shearwalls, design light wood frame structures up to 6 storeys. At the push of a button, wind and seismic loads are generated, forces are distributed, and shearwalls are designed.

$250 /yearly subscription (USD)
A 10-day trial period activates upon installation

Software Edition

Image for illustrative purposes only. This is a digital product. No physical item will be provided.

Shearwalls - Canadian Version

Software Training Videos

WoodWorks Shearwalls | Canadian Edition

Technical Specifications

General Information
Operational System
All versions currently supported by Microsoft OS.
Software Edition
Canadian Edition
Subscription
$250 CAD/Yearly
Software Capabilities
WoodWorks® Shearwalls is a powerful software for designing light wood frame structures up to 6 storeys, conforming to NBC and CSA O86. It automatically generates wind and seismic loads for buildings, distributes lateral loads between and within shear lines, and designs shearwalls with wood and gypsum sheathing. The software is capable of flexible and rigid diaphragm analyses and optimizing shearwall design by selecting the most economical sheathing and nailing patterns. Users can benefit from detailed and transparent design reports, including results for shearwall resistances, deflections, storey drifts, hold-downs, drag-strut forces etc.
SKU
WCSWC365
License Type
Concurrent
License Agreement
Click here to access the Woodworks Software® End User License Agreement.

Version 2025 (v.12.1) – Released in September 2025 and conforms to CSA O86-24 and NBC 2020

Click here to access the Change History for the CDN Shearwalls program.

Training Tab

Design a Single Shearwall – Tutorial demonstrates how to utilize shearwalls to check the shear capacity of a single shear resisting element.

Quick Start – Tutorial demonstrates the major steps for creating a shearwall model.

Two Storey Structure – Tutorial goes through the steps to create a shearwalls model including load generation.

Structure and Roof Block Strategy – Tutorial provides a strategy for creating structure and roof blocks in Shearwalls. The following video provides additional guidance on the subject.

Matching Published Design Examples – Tutorial goes over how to reproduce results from specific CWC publications.

Three Storey Building – Tutorial goes through the modelling of a three storey apartment building. A technique for creating standard walls on each storey is demonstrated.

The User Guide is a document created by the WoodWorks® Software Technical Support staff. The document includes instructions for operating the WoodWorks® programs as well as information on the software design settings.

Click here to download the Shearwalls User Guide
System Requirements Minimum Recommended Notes
Processor Speed
1 GHz
2 GHz
Single-core or equivalent performance in multiple-core processors.
RAM
1 GB
4 GB
Screen Resolution (Pixels)
1024 x 768
1440 x 900
Wide screen, adjust for other aspect ratios.
Free Hard Drive Space
80 MB
150 MB
Minimum is for download and installation. Recommended includes 100 typical project files.
Required Operating Systems
Microsoft Windows Home, Pro, Enterprise, and Education/SE editions. All versions currently supported by Microsoft.
Frequently Asked Questions

WoodWorks ShearWalls FAQ

Can I input different heights for structure blocks at the same level?

Shearwalls requires that all structure blocks have the same height for each level and that all walls on one level have the same height. This means that the diaphragm is at the same height throughout the structure and that split-level conditions are not possible. There is no specific guidance in codes and standards on how to analyze split-level conditions. If you want to provide general design procedures for this condition, please contact WoodWorks Technical support. If you want to account for the strength and stiffness of different wall heights it is recommended to make a model of the structure based on the lowest or tallest wall height, and then create separate single wall project files as shown in tutorial 1 ( CDNU.S.) for the walls that have a different height.

 
Can I model proprietary shear resisting wall systems with different rigidities?

Features which allowed for this capability have been removed from shearwalls until a new feature which would allow the input of proprietary shear resisting elements can be incorporated into the program.

 
Can Shearwalls design L-Shaped and U-Shaped buildings?

Yes, with caution. Shearwalls has been programmed to follow the codes with respect to code defined “regular” shaped buildings. Certain “irregular” shapes will not provide expected results, and engineering intuition will be required to determine if the results are acceptable for each situation.

An example of an L-Shaped building design in the online video Tutorial 1 (US & CDN). This shape is handled adequately by the software.

Caution must be used in the case of a gap between two walls, where the gap is actually external to the building such as in a U shaped structure. Where the walls are along the same shearline and separated by a gap, diaphragm shearline force/unit length is assumed to continue across the gap (even though there is no diaphragm external to the building at the gap) and drag strut forces are shown. In other words, the software assumes the gap is really an opening such as a window or door and can transfer shear across it. This issue can be worked around by modifying the “Maximum Shearline Offsets” in the Settings, Design tab.

Designers may require shear or moment forces at specific points of interest. For example, for many types of connections, designers are required to check the shear capacity of the member at the connection location. WoodWorks® Connections provides the effective shear capacity of a wood member at a connection location. Using the Point of Interest function, a designer could determine the corresponding design shear force. This is also very useful to determine what the shear and bending is at a notch or hole.

How do I determine which walls have failed the design?

After running a model, the quickest method to determine if a shearwall has failed the shear resistance design check is to review the Design summary in the Results View. Use the Go To Table button to quickly navigate to the Design Summary.

When in Plan View of a model, walls which have failed the design check(s) will be highlighted in red. Walls will not appear red if there is a failure of the hold-downs along the shearline, however, the Design Summary will display whether or not the hold-downs have adequate capacity.

How are snow loads entered in Shearwalls?

In the US, where the design roof snow loads are less than 30 psf, they are not required to be included in seismic load calculations. For higher roof snow loads, a percentage of the snow load is used in the calculation for the weight of a structure (20% as per ASCE 7-10 – 12.7.2). In fact, local building authorities may overrule the code and require up to 100% of the roof snow load to be used. In Canada, 25% of the roof snow load is used in the calculation for the weight of the structure.

To include the correct snow load for seismic loads generation, input the total roof snow load and the percentage of roof snow load to be included in the Settings, Default Values tab “Weights for Seismic Load Generation”. Note, that modifying the default values in the Settings menu requires the user to start a “New” file to take effect.

In the “Generate Loads” dialog box, under the “Seismic Loads” column the total roof snow load entered in the Settings Default values will appear with a note under it indicating what percentage of that load will be used to calculate the total roof self-weight for weight calculation purposes. This can be modified as desired.

Remember to base the dead load and snow load on the horizontal projection of the roof. The snow load is considered to extend over the entire projected area of the roof minus the overhangs, as if it were a flat-roof load.

How can I model a shearwall that spans the height of both storeys in a 2 storey building?

This sort of condition can occur in lofts or in the foyer of a 2 storey structure. Shearwalls assumes that the structure will consist of platform frame construction and the diaphragm is continuous throughout the storey. To handle these situations, it is recommended to create two project files. For example, in the case of a 2 storey structure, with an open foyer that has a 2 storey wall at the front of the structure, one project file would consist of a 2 storey building that could be used to design all the single storey walls in the structure. In the locations where the 2 storey walls occurs, you could specify 1 storey shearwalls for the purpose of attracting loads. Then using the loads from the first project file, a single wall project file could be created as shown in tutorial 1 ( CDNU.S.) for the walls that span 2 storeys. The results from both project files could be compared to determine the appropriate design.

How do I determine which walls have failed the design?

After running a model, the quickest method to determine if a shearwall has failed the shear resistance design check is to review the Design summary in the Results View. Use the Go To Table button to quickly navigate to the Design Summary.

When in Plan View of a model, walls which have failed the design check(s) will be highlighted in red. Walls will not appear red if there is a failure of the hold-downs along the shearline, however, the Design Summary will display whether or not the hold-downs have adequate capacity.

How can I model a shearwall that spans the height of both storeys in a 2 storey building?

This sort of condition can occur in lofts or in the foyer of a 2 storey structure. Shearwalls assumes that the structure will consist of platform frame construction and the diaphragm is continuous throughout the storey. To handle these situations, it is recommended to create two project files. For example, in the case of a 2 storey structure, with an open foyer that has a 2 storey wall at the front of the structure, one project file would consist of a 2 storey building that could be used to design all the single storey walls in the structure. In the locations where the 2 storey walls occurs, you could specify 1 storey shearwalls for the purpose of attracting loads. Then using the loads from the first project file, a single wall project file could be created as shown in tutorial 1 ( CDNU.S.) for the walls that span 2 storeys. The results from both project files could be compared to determine the appropriate design.

How do I model complex roof shapes?

Roof blocks have two purposes in the software. They are used to create roof weight(s) that contribute to the total weight of the structure which is used to generate the seismic loads, and based on their shapes, roof blocks are also used to generate lateral wind loads for the purpose of designing the main wind lateral force resisting system. Shearwalls does not automatically generate wind uplift loads. Taking time to draw complex roofs with many hips and valleys that would require 8 or more roof blocks is time consuming and may not be necessary for structural analysis. Instead, the complex roof could be simplified to fewer roof blocks which generically model the shape of the roof. For an example an discussion of a complex roof where this would be applicable.

How do I modify an exterior wall segment to be specified as non-shear?

To modify a wall segment to be specified as non-shear, the Design in group feature must be turned off. Below are the 4 steps to complete.

1. Split exterior wall into multiple segments by tracing over the wall.
2. Click on the wall segment you would like to designate as non-shear.
3. Uncheck the “Design in group” box in the walls view.
4. While still in walls view, modify the wall segment type to “non-shearwall”.

A standard wall can be saved with the “design in group” feature already disabled.

How do I view different Low-Rise and All-Heights wind load cases?

WoodWorks® U.S. Shearwalls is capable of generating wind loads following ASCE 7-10 Envelope (Low-rise) Procedure (ASCE 7-10 Chapter 28, Figure 28.4-1) or the directional (All-heights) procedure (ASEC 7-10 Chapter 27, Figures 27.4-1 and 27.4-8).

For low-rise wind loads the software calculates load cases for wind acting on any corner of the building. Once wind loads are generated, arrows will appear in the plan view on the windward corners of the building representing the unfactored wind loads for the load case displayed. Review the legend at the bottom of the plan view screen. Other load cases may be viewed using the Show button. The wind loads can be displayed for the main wind force resisting system (MWFRS) about either the North – South or East – West directions. By default, the software will first display the West to East, South to North wind direction, but this can be modified to which ever combination. Critical force direction can be displayed after the analysis is run. Wind loads can be displayed for both wind load cases A or B. Shearwalls automatically uses the worst case wind loads when completing the design of the shearwalls.

The All Heights procedure is readily applicable to a wide range of building geometries. The software can handle almost any configuration following this procedure as wind loads are calculated on each wall and roof surface independently. Once wind loads are generated, arrows will appear in the plan view around the building representing the unfactored wind loads for the load case displayed. Review the legend at the bottom of the plan view screen. Other load cases may be viewed using the Show button. The wind loads can be displayed for the main wind force resisting system (MWFRS) about either the North – South or East – West directions. By default the software will first display the West to East, South to North wind direction, but this can be modified to which ever combination. Shearwalls generates both case 1 and case 2 wind loads simultaneously, and uses the heaviest of these loads as the minimum load case. Case 1, Case 2 and minimum load can be displayed in plan view. Shearwalls automatically uses the worst case wind loads when completing the design of the shearwalls in the model.

For the Canadian edition of shearwalls, it is possible to generate wind loads following Figure I-7/8 (Low rise method) or Figure I-15 (unnamed all heights method).

How do I view the Wind and Seismic equations used to generate the loads Shearwalls?

In WoodWorks® Shearwalls, when you click the “Generate Loads on selected levels” button on the “Generate Loads” form, a log file detailing the load calculations is created. The log file will automatically become available at the top of the Shearwalls menu. The log file is also automatically saved under the same name of the project file (with extension .log) in the same folder. Before the analysis is run, the log file includes information on how both the wind and seismic loads were generated. A summary of the site specific wind and seismic parameters, list of equations and resulting calculations are provided. If seismic loads have been generated, once the analysis of the model is run, the log file will update to include the torsional analysis results for the seismic loads.

How many structure blocks do I need to create a model?

Structure blocks are used to quickly establish the exterior perimeter of the structure. Multiple structure blocks are meant to be utilized when there are portions of a structure which vary in height (ie. Two storey house attached to a one storey garage). It is not necessary to draw the structure blocks to match the roof shape as it is possible to draw as many roof blocks as desired once in roof block view.
Using multiple structure blocks is not necessary and can over complicate a model. It may be possible to achieve the correct shape of the structure once in walls view by splitting and shifting exterior walls. Split walls by tracing another wall on top of an existing one, then move the wall by clicking on the segment, then holding the shift key to move the wall segment.
The method for splitting and moving walls is shown in US Shearwalls tutorial 2  and in CDN Shearwalls tutorial 2. Tutorial 11 in the user guide provides further discussion and demonstration of when and how to utilize structure blocks.

Some local building codes require that the seismic forces be multiplied by “1.35”, and that the sheathing capacities be equal to those listed in the UBC 97 (ie. multiplied by “0.75”). How does Shearwalls comply with these requirements?

Click Settings/Design, under local building code capacity modification, it is possible to adjust the plywood sheathing shear strengths. The default values are 1.0, but can be modified to conform to local conditions. For example, Los Angeles Building Code mandates or at one time mandated a 75% reduction in shear capacities for seismic design. If the factor is still in effect, users should save or enter “0.75”as their default local building code modification factor for seismic loads. Similarly, there are counties in the Southeast USA that require a reduction in shear strength for high wind loads. Users in these areas should check their local building codes and apply the factor if the locally mandated shear strength differ from those published in the IBC or SDPWS.

What do the “Maximum Shearline Offsets” shown in Design Settings represent?

WoodWorks® Shearwalls allows users to specify the maximum plan or elevation offset for walls to be considered on the same shearline. These settings are found under Maximum Shearline Offset in the Settings, Design tab. The maximum plan offset is dependent on the specified plan offset and elevation joist depth. By default, Maximum Plan Offset in the plan is set as 0.5 ft (0.15m) and the Elevation offset is set as 1 joist depth, to account for errors while drawing walls. The above values are recommended to provide tolerance for the automatic shearline generation routine. However, the software allows the user to change the default values at their discretion For example, the CWC Engineering Guide for Wood Frame Construction, which provides guidance on the design of light-frame wood structures which meet the requirements of a Part 9 prescriptively design structures, allows for a maximum shearwall plan offset of 4 joist depths, up to a maximum of 1.2 m ( 2014 Engineering Guide for Wood Frame Construction Part B Figure 10.1.5). Similarly, in the US, the Wood Frame Construction Manual allows shearwall plan offsets up to 4 feet ( WFCM 2015 Clause 2.1.3.3.c.). The maximum shearline offset feature can be utilized to match similar requirements when modelling a structure.

When I try to print specific pages in Shearwall’s Results View, the wrong pages are printed.

This is a known issue with the Shearwalls program. When printing the design results, Shearwalls reduces the number of pages compared to the number of pages listed and displayed in the Results view. To avoid the issue, it is recommend to print the Results to a pdf, then print the desired pages.

 

Why professionals use it?

Shearwalls - Canadian Version

Developed by Wood Design Experts

WoodWorks® Software is developed by Canadian Wood Council staff with expert knowledge and experience with building codes and wood design standards.

Shearwalls - Canadian Version

Use a single license across multiple users without additional fees. Each license purchased grants one simultaneous use of the software.

Shearwalls - Canadian Version

Add and design proprietary wood products (e.g., structural composite lumber, I-joists with ease).

Shearwalls - Canadian Version

Explore New Possibilities

There’s a New Way to Design Wood Buildings

Always Compliant with Canada and US Regulations

Built to align with Canada’s CSA O86 and NBC, as well as US codes and standards including IBC, ASCE-7, NDS, and SDPWS. Your projects meet safety and quality standards.

Access free technical support and resources to navigate wood design through WoodWorks® Software with ease and efficiency.

Access cutting-edge tools, resources, and expert guidance to navigate every stage of planning, design, and execution with ease and efficiency.

Easy to Use and Flexible Subscription Options

Enjoy user-friendly features and flexible subscription options designed to fit the needs of your project and your budget.

Looking for WoodWorks ShearWalls Support?

Let us Know How We Can Help You

Our technical team is available to support you throughout your WoodWorks Software® journey during regular office hours. 

Other Products

Take a moment to explore our other software products, designed to assist you in designing your next project.

Shearwalls - Canadian Version
WoodWorks® Sizer

With WoodWorks® Sizer, size beams, joists…

$210 /yearly 10-day trial period available.

Shearwalls - Canadian Version
WoodWorks® Shearwalls

With WoodWorks® Sizer, size beams, joists…

$250 /yearly 10-day trial period available.

Shearwalls - Canadian Version
WoodWorks® Connections

With WoodWorks® Sizer, size beams, joists…

$60 /yearly 10-day trial period available.

Sizer – Canadian Version

WoodWorks®

Sizer 2025

$210 /yearly subscription (CAD)
Conforms to CSA O86-19, NBC 2020, and CSA S16-14


  • Specify dead, live, snow, wind, seismic, and other load types distributed as point, line, area, triangular and trapezoidal loads for up to 100 loads per member
  • Analyzes all load combinations as per the National Building Code of Canada (NBC), including pattern loading and concentrated live loads
  • Designs for all critical load combinations for shear, bending, deflection, vibration, and bearing as per the CSA O86 Standard
  • Optimizes structural member sizes using material database and generates a material list for design
  • Includes editable database to add or modify custom wood materials
  • Designs light-frame floor systems using Sizer in Autodesk Revit® through MWF Pro Wood extension.


Design Structures – Concept Mode

  • Configure and design wood structures up to 6 storeys for gravity loads
  • Structural members are transferable to the Beam or Column Mode for detailed analysis


Design Structural Members – Beam and Column Mode

  • Designs structural members including single or multi-span, cantilevered, and inclined beams and joists, wall studs, columns, beam-columns and CLT panels
  • Designs W-shaped steel beams and HSS steel columns using CSA S16
  • Generates shear, bending moment and deflection diagrams
  • Designs for bearing, notches, and Simpson Strong-Tie beam and joist hangers
  • Designs for fire resistance
  • And much more!

Software Edition

A 10-day trial period activates upon installation
Image for illustrative purposes only. This is a digital product. No physical item will be provided.
Sizer - Canadian Version

WoodWorks®

Sizer

WoodWorks® Sizer – Size beams, joists, columns, wall studs and panels constructed from lumber, timber, glulam, structural composite lumber, I-joists and CLT.

$210 /yearly subscription (USD)
A 10-day trial period activates upon installation

Software Edition

Image for illustrative purposes only. This is a digital product. No physical item will be provided.

Sizer - Canadian Version

WoodWorks®

Shearwalls

WoodWorks® Shearwalls, design light wood frame structures up to 6 storeys. At the push of a button, wind and seismic loads are generated, forces are distributed, and shearwalls are designed.

$250 /yearly subscription (USD)
A 10-day trial period activates upon installation

Software Edition

Image for illustrative purposes only. This is a digital product. No physical item will be provided.

Sizer - Canadian Version

Software Training Videos

WoodWorks Sizer | Canadian Edition

Technical Specifications

General Information
Operational System
All versions currently supported by Microsoft OS.
Software Edition
Canadian Edition
Subscription
$210 CAD/Yearly
Software Capabilities
WoodWorks® Sizer is a versatile software for designing structural systems and components made from materials such as lumber, timber, glulam, structural composite lumber, steel, wood I-joists, and CLT. It analyzes all load combinations as per the National Building Code of Canada (NBC) and performs structural and fire design as per CSA O86 standard. The software optimizes structural member sizes for single or multi-span, cantilevered, or inclined beams and joists, wall studs, columns, beam-columns and CLT panels. Sizer also integrates with Autodesk Revit® for designing light-frame floor systems.
SKU
WCSZC365
License Type
Concurrent
License Agreement
Click here to access the Woodworks Software® End User License Agreement.

WoodWorks® Canadian Sizer
Version 2025 (v.12.1) – Released in September 2025 and conforms to CSA O86-19 and NBC 2020

Click here to access the Change History for the CDN Sizer program.

The User Guide is a document created by the WoodWorks® Software Technical Support staff. The document includes instructions for operating the WoodWorks® programs as well as information on the software design settings.

Click here to download the Sizer User Guide. 

Determine Beam Size Based on Given Loads – Determine the beam size based on given loads and allow Sizer to suggest solutions

Determine the Capacity of a pre-determined Beam Size 

Determine Column Size Based on Given Loads – Determine the column size based on given loads and allow Sizer to suggest solutions.

Glulam Column Check – Determine the capacity of a pre-determined Column size.

Two Storey Building – Create a gravity load model of a two storey structure

Example from Concept Mode Demo – Create the gravity load model which is demonstrated in the concept mode overview video.

Modifying Custom Databases – Tutorial goes over how to modify a custom SCL database. 

Database Editor Example 

System Requirements Minimum Recommended Notes
Processor Speed
1 GHz
2 GHz
Single-core or equivalent performance in multiple-core processors.
RAM
1 GB
4 GB
Screen Resolution (Pixels)
1024 x 768
1440 x 900
Wide screen, adjust for other aspect ratios.
Free Hard Drive Space
80 MB
150 MB
Minimum is for download and installation. Recommended includes 100 typical project files.
Required Operating Systems
Microsoft Windows Home, Pro, Enterprise, and Education/SE editions. All versions currently supported by Microsoft.
Frequently Asked Questions

WoodWorks Sizer FAQ

Are live and snow loads input as factored loads?

All loads which are input into Sizer are unfactored. Once the design has been run, Sizer automatically factors the loads based on the appropriate load cases for the applicable code and standards the software conforms to.

Can I import a CAD drawing into Sizer’s Concept Mode?

At this time it is not possible to import a CAD drawing into concept mode. To create a model of a structure, it is recommended to either generate a grid based on the specified snap increment (Settings, View tab), or to place gridlines manually by clicking on the blank concept mode screen. When a specific gridline is clicked on, it is possible to remove the gridline by clicking the delete key or the gridlines name and location can be modified in the data bar.

Can Sizer be utilized to calculate the shear and moment at different points in a member?

The Point of Interest button located on the toolbar is used to investigate the shear and moment at any point along the length of a beam or column. A point of interest is generated by specifying a “Location from Left” to perform the analysis, and clicking “Add” to add this to your list. Several points of interest can be specified. After performing a design, the results for the points of interest will be shown in the Diagrams window and in the Analysis results output.

Designers may require shear or moment forces at specific points of interest. For example, for many types of connections, designers are required to check the shear capacity of the member at the connection location. WoodWorks® Connections provides the effective shear capacity of a wood member at a connection location. Using the Point of Interest function, a designer could determine the corresponding design shear force. This is also very useful to determine what the shear and bending is at a notch or hole.

WoodWorks Sizer is capable of interfacing with cadwork® and Revit®. Third party interface programs are capable of automatically sizing beams either by opening Sizer and running the design, or by running Sizer in the background. The resulting beam size is automatically brought in to the cadwork® or Revit® model. The cadwork® link is imbedded directly in the program. The Revit® link is done by a third party program created by Structsoft solutions. Please see the following link for more information on 3rd party interface with Sizer.

How can I design Structural Composite Lumber (SCL) such as PSL, LVL, or LSL using Sizer?

A growing amount of manufacturers of SCL products are sharing the cost to include some of their SCL products in Sizer. A list of participating manufacturers is included on our website under the Proprietary Products section.
The manufacturer’s participation options are to:

a) Provide a database to designers that can be added to the software database
b) Work with the software developer through the CWC to include some or all of their solid rectangular (not engineered I-joists) products in the generic version of Sizer
c) Work with the software developer through the CWC to develop a fully customized version of Sizer that can include all products including I-joists.

If the manufacturer you typically specify products from is not already included in the software, it is recommended that you contact them and ask them if they have an updated material database for you or would be willing to create one for you. You can request that they contact us should they wish to have their database included with the installation of the software.

You can create your own custom SCL database using the databases editor:
If you have a SCL custom database file and would like to implement it into the software, you are going to need to place the file in the following two locations on your computer. Make sure you do this in both locations or else it will not work.

For USA Design Office 11:
C:\Users\%username%\AppData\Local\Woodworks\CWC\USA\11
C:\ProgramData\WoodWorks\CWC\USA\11

For Canadian Design Office 10:
C:\Users\%username%\AppData\Local\Woodworks\CWC\Canada\10
C:\ProgramData\WoodWorks\CWC\Canada\10

Once the file has been placed in the above locations, it will be necessary to open the database editor and ensure that the database is set to “use”. The next time you open Sizer, the database will be available for selection.

How do I enter an actual size of a member that is the same as one of the existing nominal sizes?

For the US edition of the software, it may be that the actual size you wish to enter is the same as a nominal size in the Sizer database.

Example: if you wish to enter the full 2″ width of undressed lumber, rather than the 1.5” planed width. Sizer will in this case select the nominal size when you type in the number “2”. However, if you type in 2.001, Sizer will interpret this as an actual size, and even though it rounds the number and shows it as “2” the nomenclature for the width and depth input will display “in” rather than “nom in” and treat it as an actual size. When following this method, it is necessary to input the exact depth as well, if the depth is left as unknown, then the design results will revert back to nominal dimensions.

For the Canadian edition of the software, it is possible to input the exact dimensions of a member by specifying the material as “Rough Lumber”. Using the “Rough Lumber” material allows the user to input specific member dimensions.

Sizer crashes whenever I click on Loads input View.

This is a known issue with Sizer and is due to some background programming in Microsoft Windows. To resolve the issue, enable the “Show loads view in a pop-up Window” feature in the Settings, Preferences tab.

Why professionals use it?

Sizer - Canadian Version

Developed by Wood Design Experts

WoodWorks® Software is developed by Canadian Wood Council staff with expert knowledge and experience with building codes and wood design standards.

Sizer - Canadian Version

Concurrent Licensing

Use a single license across multiple users without additional fees. Each license purchased grants one simultaneous use of the software.

Sizer - Canadian Version

Add and design proprietary wood products (e.g., structural composite lumber, I-joists) with ease.

Sizer - Canadian Version

Integrate your designs with industry-leading tools like Revit® (through MWF Pro Wood) and cadwork® for faster workflows and project efficiency.

Sizer - Canadian Version

Explore New Possibilities

There’s a New Way to Design Wood Buildings

Always Compliant with Canada and US Regulations

Built to align with Canada’s CSA O86 and NBC, as well as US codes and standards including IBC, ASCE-7, NDS, and SDPWS. Your projects meet safety and quality standards.

Access free technical support and resources to navigate wood design through WoodWorks® Software with ease and efficiency.

Access cutting-edge tools, resources, and expert guidance to navigate every stage of planning, design, and execution with ease and efficiency.

Easy to Use and Flexible Subscription Options

Enjoy user-friendly features and flexible subscription options designed to fit the needs of your project and your budget.

Looking for WoodWorks Sizer Support?

Let us Know How We Can Help You

Our technical team is available to support you throughout your WoodWorks Software® journey during regular office hours. 

Other Products

Take a moment to explore our other software products, designed to assist you in designing your next project.

Sizer - Canadian Version
WoodWorks® Sizer

With WoodWorks® Sizer, size beams, joists…

$210 /yearly 10-day trial period available.

Sizer - Canadian Version
WoodWorks® Shearwalls

With WoodWorks® Sizer, size beams, joists…

$250 /yearly 10-day trial period available.

Sizer - Canadian Version
WoodWorks® Connections

With WoodWorks® Sizer, size beams, joists…

$60 /yearly 10-day trial period available.

Directory – British Columbia

Directory

Discover leading products, services, and expertise in Canada’s wood design and construction industry through our Business Directory.

Looking to be added to the Canadian Wood Council Directory? Get Added

British Columbia Listings

58 results found…

Filters

Sort By Dropdown Icon
Showing 0 of 58

Innovative Strategies for Light-Frame Mid-Rise Buildings in High-Seismic Regions

Mass Timber Demonstration Fire Tests Program

Handouts

3 Storey Mass Timber Office – Revit Model

Lecture Notes

Slide Deck

Considerations in the Design & Prefabrication of Mass Timber Buildings for Architects

Considerations in the Design & Prefabrication of Mass Timber Buildings for Architects

Shearwalls – Canadian Version
Sizer – Canadian Version
Directory – British Columbia
Innovative Strategies for Light-Frame Mid-Rise Buildings in High-Seismic Regions
Mass Timber Demonstration Fire Tests Program
Handouts
3 Storey Mass Timber Office – Revit Model
Lecture Notes
Slide Deck
Considerations in the Design & Prefabrication of Mass Timber Buildings for Architects
Considerations in the Design & Prefabrication of Mass Timber Buildings for Architects
Considerations in the Design & Prefabrication of Mass Timber Buildings for Architects
For new wood, remember: The wood must be dry.  Drying time depends on a few factors. Ideally the wood should be kiln-dried (stamped “S-DRY”, “KD” or “KDAT”, see...
Acrylic A type of water-borne coating product containing acrylic polymers. Alkyd A type of polyester resin. Term often used to signify solvent-borne coatings, e.g., oil...
Canada has had a wood preservation industry for about 100 years.  Canada is tied with the UK as the world’s second largest producer of treated wood (the USA is first...
FPInnovations has been field testing the performance of treated wood products for years. Click one of these categories for performance data from our field tests....
In the early 1900s, light-frame wood construction and heavy timber, up to ten-storeys in height, was commonplace in major cities throughout Canada. The longevity and...
What do the experts have to say about wood-frame mid-rise construction? Graham Finch, Building Science Research Engineer Michael Green, Principal, Michael Green Architecture...
On behalf of the Canadian Commission on Building and Fire Codes (CCBFC) the National Research Council (NRC) Codes Canada publishes national model codes documents that set out...
Supplementary treatment may be added wherever on-site cutting or drilling of wood is unavoidable, or where it is suspected the original protection measures may be inadequate....
Fasteners, Connectors and Flashing for Wood Treated With Copper-Based Preservatives The presence of moisture is a precondition for corrosion of metals. Treated wood is...
Treatability of Major North American Softwoods Some wood is easier to treat than others. The particular structure of the cells for a given piece of wood will determine how...
Individuals in the design and construction community are increasingly choosing materials, design techniques and construction procedures that improve a structure’s ability...
Since remedial treatment is intended to solve a known insect or decay problem, the first thing to do is investigate the extent of the problem and, if necessary, provide...

Get Access to Our Resources

Stay in the loop and don’t miss a thing!

1
2
3

Get Access to Our Resources

Stay in the loop and don’t miss a thing!

What’s Your Occupation?

Help us personalize the content for you.

What Interests You the Most?

Help us personalize the content for you.

Filters

Expertise Icon
Field of Expertise
Province Icon
Province
Member Type Icon
WoodWork National Partners

Filters

Post Type Icon
Post Type
Persona Icon
Persona
Language Icon
Language
Tags Icon
Tags
Mass Timber Plus Icon Environment Plus Icon Safety Plus Icon Durability Plus Icon Design Systems Plus Icon Budget Plus Icon Construction Management Plus Icon Fire Resistance Plus Icon Tall Buildings Plus Icon Short Buildings Plus Icon
Date Icon
Date
Line Separator