Lesson 5 Assessment

Difficulty Level: 3/5

Estimated Time to Complete: 15 minutes


Problem Statement: Glulam Column

This assignment aims to evaluate if a column meets the resistance requirements. 

Given Data:

  • Glulam Type &  [Grade]: S-P-F  [12c-E] 
  • Column height: 9 m 
  • Column Size: 175 (b) × 266 (d) mm 
  • The column is pinned at both ends 
  • 2 lateral supports along the width “b”, so Lb = 3 m along “b” 
  • 1 lateral support along the depth “d”, so Lb = 4.5 m along “d” 
  • Specified Dead Load: 50 kN 
  • Specified Live Load: 75 kN 
  • Service Condition: Dry 
  • Untreated Lumber

Design Requirement:

Use the software to check if the column meets ULS requirements under the specified dead and live loads in compression, bending and shear. 


Question 1

Select the most appropriate answer based on the software output and standard design requirements.