With the height limit for combustible construction limited to four stories under the National Building Code of Canada, it was uncommon for designers to perform detailed analysis to determine the stiffness of shear walls, distribution of forces, deflections, and inter-storey drifts. It was only in rare situations where one may have opted to check building deflections. With the recent change in allowable building heights for combustible buildings from four to six storeys under an amendment to the 2006 BC Building Code, it has become even more important that designers consider more sophisticated methods for the analysis and design of wood-based shear walls. As height limits increase, engineers should also be more concerned with the assumptions made in determining the relative stiffness of walls, distribution of forces, deflections, and inter-storey drifts to ensure that a building is properly detailed to meet the minimum Code objectives.
Although the use of LDA has not been common practice, the more rigorous analysis, as demonstrated in the APEGBC bulletin on 5- and 6-storey wood-frame residential building projects (APEGBC 2011), could be considered the next step which allows one to perform an LDA. This fact sheet provides a method to assist designers who may want to consider an LDA for analyzing wood-frame structures. It is important to note that while LDA may provide useful information as well as streamline the design of wood-frame structures, it most often will not be necessary. However, designers may consider using LDA for the following reasons:
Consider the effect of higher mode participation on force distributions and deflections.
Better determine building deflections and floor drifts.
Allow for three-dimensional modelling.
Reduce the minimum Code torsional effect required under the equivalent static design.
Better consider the effect of podium structures (vertical changes in RdRo).
Compare the stiffness of various shear wall systems where mixed systems are used.